New-generation power grid intelligent emergency inspection system put into operation
On Sept 12, during an emergency drill at the 500-kilovolt Lanting Substation, an alarm signaling a "5011 bay fault trip" triggered the immediate auto-start of the integrated "air-space-ground" intelligent inspection system. Simultaneously, the system issued a "5011 bay joint inspection" task order: a drone promptly launched to conduct precise high-altitude scans of the tripped equipment; a quadruped robot navigated among the ground-level equipment to locate the fault; while surveillance cameras adjusted their angles in sync to focus on key components — a comprehensive joint emergency inspection was fully underway within 30 seconds.
"In traditional substation intelligent inspections, task initiation relies on manual triggering, requiring pre-configuration of flight paths and preset points, which results in slow emergency response. To address this, we have pilot-tested and upgraded the new-generation system's intelligent emergency application at the 500-kilovolt Lanting Substation and plan to promote it across the city," said Liu Jianda, a staff member at the Operation and Maintenance Department of State Grid Shaoxing Power Supply Company. By interfacing with data between Zones I and IV of the new-generation centralized control system, the intelligent inspection system can now automatically dispatch drones, quadruped robots, and cameras for joint inspection when equipment malfunctions or fails, enabling preliminary fault assessment without manual commands. Additionally, the system allows operators to freely select points on a 3D map, upon which it intelligently plans the optimal inspection path. This eliminates the need for manual debugging or predefined points, enabling detailed inspection of suspected fault locations. This upgrade transitions the system from a "traditional manual trigger" model to a "system auto-start + manual precision intervention" approach, achieving true "intelligent linkage, second-level response, autonomous planning, and inspect-where-pointed" capabilities for substation inspections.
"Traditional emergency inspections depended heavily on manual expertise and were constrained by response speed. Now, with the upgraded system, not only can it auto-initiate during substation emergencies, but it also allows us to 'inspect where pointed', significantly enhancing human-machine collaboration," said Zhang Min, deputy station master of the Lanting Centralized Control Station, State Grid Shaoxing Power Supply Company. "Particularly in complex fault scenarios, the system can automatically complete the initial fault assessment promptly. Based on real-time analysis, personnel can then further pinpoint and inspect fault locations via the 'inspect-where-pointed' function. This enables 'second-level locking and precise troubleshooting' in complex fault environments, effectively improving the accuracy and flexibility of substation intelligent inspections to adeptly handle various emergency situations."
Professional evaluation indicates that after this application upgrade, the system's initial fault identification rate will reach 90 percent, the substation emergency response timeliness rate will increase by nearly 30 percent, and emergency response time is expected to be reduced by nearly 70 percent, significantly enhancing the substation's emergency response capabilities and fault handling efficiency.